Schroeder Industries have introduced a new high pressure filter for permanent installation in demanding applications.
Dirt alarms are available as either pop up or pop up with thermal lockout to avoid cold start errors. Electric switches are also available in 2 formats, 3 pin hirschmann type or a low cost OEM grounding switch (preferred option)
The advantages of fitting standard elements instead of spin on cans are many fold. Future legislation will tighten up on the disposal of used elements. The single cartridge element can be crushed to reclaim the oil before disposal.
 |
Flow Rating: Up to 70 gmm (265L/min) for 150 SUS (32 cSt) fluids
Max. Operating Pressure: 6000 psi (415 bar)
Min. Yield Pressure: 15,500 psi (1070 bar)
Rated Fatigue Pressure: 3300 psi (230 bar), per NFPA T2.6.1-R1-1991
Temp. Range: -20°F to 225°F (-29°C to 107°C)
Bypass Setting: Cracking: 50 psi (3.5 bar); Full Flow: 65 psi (4.5 bar)
Porting Head: Ductile Iron
Element Case Steel
Weight of VF60-9V: 24.0 lbs. (10.9 kg)
Weight of VF60-14V: 29.0 lbs. (13.2 kg)
Element Change Clearance 6.00 inches (155 mm) |